苏州IPX4 防水检测

Equipment informationTest equipment:Water proof EquipmentEquipment model:TL-LY1-

我们将及时回复您!

您想咨询的问题

您的姓名

您的号码

您的邮箱

您所在城市

Equipment information

Test equipment:Water proof Equipment

Equipment model:TL-LY1-4F

Laboratory environment

Temperature: 22.5℃~23.6℃; 

 Relative humidity: 45%RH~65%RH  

Test condition

Test item:IPX4

Test condition

1) Pendulum tube radius: 400mm 

 2) Water flow: 0.07L/min 

 3) Pendulum tube swing Angle: pendulum tube swings 180° on bothsides of the vertical line 

 4) Rotary speed: 1r/min 

 5) Test time: 10min 

 6) Test direction: Top face up. Bottom face up. Right face up Left face up

Test result

image.png

image.png

常见问题

A1: Equipment informationTest equipment1、Low-pressure temperature testchamber2、Elect

A1: Equipment informationTest equipment:Water proof EquipmentEquipment model:TL-LY1-

A1: Equipment informationTest equipment:Dust control laboratoryEquipment model:TL-SC

A1: Equipment informationTest equipment:Water proof Equipment;Equipment model:TL-LY1

A1: Equipment informationTest equipment:Water proof Equipment Equipment model:TL-LY

A1: 测试项目防水测试测试设备设备名称:防水试验机测试环境温度22.3C,湿度46%RH检测条件IPX8:标签最低面处于水深2米放置六小时。

A1: 测试项目防水试验(浸水)测试标准GB/T 4208-2017 IPX8测试环境温度15C~30C,湿度25%RH~75%RH测试方法标签最高面应处于水深不小于1

A1: 测试设备1、电子天平测试环境温度/Temperature:22.2℃; 湿度/Humidity:55%RH参考标准44-00-430-074-A污染物提取方式测

A1: 测试设备1、电子天平2、清洁度检测系统测试环境温度:22.5℃; 湿度58%RH参考标准ISO16232:2018&STD4540清洁度要求及结论污染物提取方式