Equipment information
Test equipment:Temperature and humidity chamber Equipment model:GL-04KA
Test equipment:Noise vibration analyzer Equipment model:Heim DIC 6B
Laboratory environment
Temperature: (25±5)℃;
Relative humidity: 25%RH ~75%RH.
3Refer to the test specification
According to customer requirement perform the test.
Test condition
Test Voltage: Rated Voltage
Operation: Through PWM or voltage control, on/off 30 seconds each
Testing temperature: -25℃~85℃±2℃
Ambient humidity: 85 %RH±3% RH
Temperature climbing rate: 1℃/min
Test cycle: 30 cycles, 1.5 hours for each temperature point, 110 minutes for each equipment temperature rise and fall
Test result

test data