Equipment information
Equipment name
1、Gas Corrosion Test Chamber
2、High-precisionelectronic balance
Model
1、VCC3 0100
2、YK-FA1004
Laboratory environment
Temperature: 22.5℃~25.7℃;Relative humidity: 25%RH~75%RH;
Test condition
Temperature: 25 ℃ Relative humidity: 75% RH,
The gas concentrations in parts per billion (ppb) that shall be used during testing are: Cl2 = 10ppb, NO2 = 200ppb, H2S =10ppb, SO2 = 200ppb.Duration: 21days
Test result