Equipment information
Test equipment
1、Low-pressure temperature testchamber
2、Electronic load
Equipment model
1、AZVAT1000U
2、PEL-8150
Laboratory environment
Temperature: (25±5)℃
Relative humidity: (50±5) % RH
Test condition
Selected test as requested by the customer
Test result
Input 220v, output maximum load, altitude: 5000 meters, dwell time: 0℃ dwell 4 hours,
then 50℃ dwell 4 hours